  • Cool Stages: 3
  • Country/Region of Manufacture: China
  • Operating temperature: 0°÷60°C 32°÷140°F
  • Brand: DIXELL
  • Condenser: NTC / PTC on HOT KEY
  • Compressor: 8A, 20A optional
  • Resolution: 0.1°C or 1°F
  • Display type: red LED (13mm high) with icons blue LED optional
  • Hot Key output: present
  • Features: Adjustable Thermostat
  • Voltage: 230 V
  • Model: Digital controller with defrost fans management
  • Display Size: 3 Digits
  • Analog/Digital: Digital
  • Data Storage: EEPROM memory
  • Restocking Fee: No
  • Thermostat Shape: Rectangular
  • Smart Home Compatibility: Universal
  • Connection: Screw-terminal block <2.5mm
  • Remote display output: X-REP optional
  • Return shipping will be paid by: Buyer
  • Type: XR60CX-5N1C1
  • Display: 3 Digits
  • Item must be returned within: 30 Days
  • All returns accepted: Returns Accepted
  • Color: Silver
  • Condition: New
  • Thermostat: NTC / PTC
  • Control Style: Digital
  • Measurement range: probe dependent

    Description

    Store category
    Sign Up Now !
    You may also like
    Dixell XR60CX-5N1C1 Digital Controller Defrost Fans Management For Refrigeration
    Product Description
    Model XR60CX, format 32 x 74 mm, is microprocessor based controller, suitable for applications on medium or low temperature ventilated refrigerating units. It has three relay outputs to control compressor, fan, and defrost, which can be either electrical or reverse cycle (hot gas). It is also provided with three NTC or PTC probe inputs, the first one for temperature control, the second one,to be located onto the evaporator, to control the defrost termination temperature and to managed the fan, the third one, optional, to connect to the HOT KEY terminals to signal the condenser
    temperature alarm or to display a temperature. The digital input can operate as fourth temperature probe.
    The HOT KEY output allows to connect the unit, by means of the external module XJ485-CX, to a network line ModBUS-RTU compatible such as the dIXEL monitoring units of X-WEB family. It allows to program the controller by means the HOT KEY programming keyboard.The instrument is fully configurable through special parameters that can be easily programmed through the keyboard.
    Suitable for appliances including
    for applications on medium or low temperature ventilated refrigerating units
    Specification
    Housing: self extinguishing ABS.
    Case: XR60CX frontal 32x74 mm; depth 60mm;
    Mounting: XR60CX panel mounting in a 71x29mm panel cut-out
    Protection: IP20; Frontal protection: XR40CX IP65
    Connections: Screw terminal block ± 2,5 mm2 wiring.
    Power supply: according to the model: 12Vac/dc, ±10%; 24Vac/dc, ±10%; 230Vac ±10%,
    50/60Hz, 110Vac±10%, 50/60Hz
    Power absorption: 3VA max
    Display: 3 digits, red LED, 14,2 mm high; Inputs: Up to 4 NTC or PTC probes.
    Digital input: free voltage contact
    Relay outputs: compressor SPST 8(3) A, 250Vac; or 20(8)A 250Vac
    Data storing: on the non-volatile memory (EEPROM).
    Kind of action: 1B; Pollution grade: 2;Software class: A.;
    Rated impulsive voltage: 2500V; Overvoltage Category: II
    Operating temperature: 0÷60 °C;Storage temperature: -30÷85 °C.
    Relative humidity: 20-85% (no condensing)
    Measuring and regulation range: NTC probe: -40÷110°C (-40÷230°F);
    PTC probe: -50÷150°C (-58÷302°F)
    Resolution: 0,1 °C or 1°C or 1 °F (selectable); Accuracy (ambient temp. 25°C): ±1 °C ±1 digit
    The X-REP output excludes the TTL output.It’s present in the following codes:
    XR60CX- xx2xx, XR60CX –xx3xx;
    COMPRESSOR
    The regulation is performed according to the temperature measured by the thermostat probe with a positive differential from the set point: if the temperature increases and reaches set point plus differential the compressor is started and then turned off when the temperature reaches the set point value again.
    In case of fault in the thermostat probe the start and stop of the compressor are timed through parameters “COn” and “COF“.
    DEFROST
    Two defrost modes are available through the “tdF” parameter: defrost through electrical heater (tdF= EL) and hot gas defrost (tdF = in). Other parameters are used to control the interval between defrost cycles (IdF), its maximum length (MdF) and two defrost modes: timed or controlled by the evaporator’s probe (P2P).At the end of defrost dripping time is started, its length is set in the FSt parameter. With FSt =0 the dripping time is disabled.
    CONTROL OF EVAPORATOR FANS
    The fan control mode is selected by means of the “FnC” parameter: FnC = C_n: fans will switch ON and OFF with the compressor and not run during defrost
    FnC = o_n fans will run even if the compressor is off, and not run during defrost;
    After defrost, there is a timed fan delay allowing for drip time, set by means of the “Fnd” parameter.
    FnC = C_Y fans will switch ON and OFF with the compressor and run during defrost;
    FnC = o_Y fans will run continuously also during defrost
    An additional parameter “FSt” provides the setting of temperature, detected by the evaporator probe,
    above which the fans are always OFF. This is used to make sure circulation of air only if his
    temperature is lower than set in “FSt”.
    Forced activation of fans
    This function managed by the Fct parameter is designed to avoid short cycles of fans, that could
    happen when the controller is switched on or after a defrost, when the room air warms the
    evaporator. Functioning: if the difference of temperature between the evaporator and the room
    probes is more than the value of the Fct parameter, the fans are switched on. With Fct=0 the function
    is disabled.
    Cyclical activation of the fans with compressor off.
    When Fnc = c-n or c-Y (fans in parallel to the compressor), by means of the Fon and FoF
    parameters the fans can carry out on and off cycles even if the compressor is switched off. When the
    compressor is stopped the fans go on working for the Fon time. With Fon =0 the fans remain always
    off, when the compressor is off.
    SAFETY PRECAUTIONS
    • Check the supply voltage is correct before connecting the instrument.
    • Do not expose to water or moisture: use the controller only within the operating limits avoiding
    sudden temperature changes with high atmospheric humidity to prevent formation of condensation.
    • Warning: disconnect all electrical connections before any kind of maintenance.
    • Fit the probe where it is not accessible by the End User. The instrument must not be opened.
    • In case of failure or faulty operation send the instrument back to the distributor or to “Dixell S.r.l.” (see address) with a detailed description of the fault.
    • Consider the maximum current which can be applied to each relay (see Technical Data).
    • Ensure that the wires for probes, loads and the power supply are separated and far enough from each other, without crossing or intertwining.
    • In case of applications in industrial environments, the use of mains filters (our mod. FT1) in parallel with inductive loads could be useful.
    Package Include
    1 X Dixell XR60CX Digital Thermostat Controller(Whole package with accessories)
    Payment
    Shipping
    Terms of sales
    Feedback
    Contact us
    Payment
    We only accept
    Paypal
    .
    Payment should be made
    within 3 days
    after bidding ends.
    Otherwise a Unpaid Item case will be opened to you by ebay.
    Shipping and Handling will be determined based upon the SHIP TO address.
    PLEASE NOTE
    : S&H DOES NOT INCLUDE DUTIES, LOCAL TAXES OR ANY OTHER IMPORTATION FEES.
    Shipping
    Order will be shipped once we receive your cleared payment.
    For US.UK.DE buyers, we use Standard(Delivery time is 5-12 business days) or express delivery(Delivery time is 3-5 business days) .
    For other countries' buyers, we use Standard shipping or Economy shipping(Delivery time varies from 7 to 25 business days)or Express delivery(Delivery time is 3-5 business days).
    We will ship according to your
    EBAY address
    .
    SERVICE TRANSIT TIME is provided by the carrier and excludes weekends and holidays. Transit times may vary, particularly during the holiday season.
    Please make sure it is correct and include phone number for delivery.
    If you do not receive your order in the estimated time, please contact us first, we would do our best to serve you solve the problem.
    Please include your special requests in eBay note if there is any.
    Terms of sales
    You have 7 days to contact us and 10 days to return it from the date it was received.
    We will instruct you on how to return and get refund or replacement.
    If after 7 days, or the item has been used, we have the right to decline your claim.
    Items should be returned on buyers' cost for repair or replacement.
    All returned items must be in the original packaging and you must provide us with the shipping tracking number, specific reason for the return, and your eBay ID.
    We will refund YOUR FULL AMOUNT, upon receipt of the item in its original condition and packaging with all components and accessories included, AFTER BOTH Buyer and Seller cancel the transaction from eBay. or you may choose to have a replacement.
    Return shipping is to be paid by the Buyer.
    Feedback
    We automatically submit positive feedback to our buyers once the payment is cleared.
    If anything about your transaction did not meet your expectations,
    PLEASE LET US KNOW AND GIVE US THE OPPORTUNITY TO MAKE THINGS RIGHT
    before you leave feedback - We are 100% sure that we can solve any issue regarding your purchase.
    Contact us
    Our customer-oriented service strives for positive feedbacks with all 5 star ratings.
    Please feel free to contact us via eBay message once you have any question before you giving us negative feedback or open case.
    We will reply in 24 business hours.
    Business time: GMT8 (8:00-18:00) from Monday to Friday. About weekend,we will also answer your question,but it may delay for a short time,please understand.
    Feedback